Comparison of three small chamber test methods for the measurement of VOC emission rates from paint
Indoor Air
In: Indoor Air, vol. 13, no. 2, pp. 156–165, 2003.
Editorial summary
This study compares VOC emission rates from aged alkyd paint measured in a 1 m³ chamber, FLEC and CLIMPAQ under matched climatic and area-specific ventilation conditions. The three systems differed in stabilization time but produced emission rates that agreed within the study's stated overall uncertainty.
Original non-verbatim editorial summary based on the publisher record and indexed abstract; no reusable license for the source abstract was established.
FLEC use
FLEC method, modelling or validation
The study's substantive purpose is a head-to-head comparison of FLEC, CLIMPAQ and a 1 m³ chamber as emission-test methods.