1999Journal ArticleMethod / modelling

Determination of formaldehyde emission with field and laboratory emission cell (FLEC)—recovery and correlation to the chamber method

Risholm-Sundman, Margareta

Indoor Air

In: Indoor Air, vol. 9, no. 4, pp. 268–272, 1999.

Editorial summary

The study describes a FLEC procedure for formaldehyde sampling with DNPH cartridges and HPLC and compares it with the traditional chamber method for wood-based products. Recovery tests and cross-method results form a validation of FLEC for formaldehyde emissions.

Original non-verbatim editorial summary based on the official PubMed abstract; no reusable license for the source abstract was established.

FLEC use

FLEC method, modelling or validation

The primary contribution is recovery testing and correlation of a FLEC formaldehyde method with the chamber method.

Topics

FLECformaldehyderecoverychamber comparisonwood products