VOC emissions from building materials: Results from lab and model room trials
In: 2014, ISSN: 20426453.
Editorial summary
Small-scale FLEC tests were used to rank VOC emissions from individual timber-building products, while 30 m3 rooms assessed complete construction assemblies. Emissions generally declined over time, and covering surfaces with gypsum board had little long-term effect on total VOC levels.
Original editorial summary (non-verbatim), based on the publisher abstract and accessible article copy.
FLEC use
Direct FLEC measurements
The study explicitly reports FLEC testing of 26 individual products before comparing them with measurements in 30 m3 model rooms.