2017Journal ArticleFLEC measurements

Airborne fungal species associated with mouldy and non-mouldy buildings – effects of air change rates, humidity, and air velocity

Knudsen, Sofie M · Gunnarsen, Lars · Madsen, Anne Mette

Building and Environment

In: Building and Environment, vol. 122, pp. 161 - 170, 2017, ISSN: 0360-1323.

Editorial summary

The researchers measured fungal release from contaminated gypsum boards while varying near-surface air velocity and sampling duration, and also surveyed fungal communities in five non-moisture-damaged homes. In the laboratory experiments, a specially designed Particle Field and Laboratory Emission Cell (P-FLEC) was placed on the gypsum boards to release and collect particles. Laboratory release depended on surface condition and airflow, while household species composition was associated with air-change rate and relative humidity.

Original editorial summary, not a verbatim abstract, based on the publisher and institutional-repository records plus public article text and independent full-text indexing of P-FLEC.

FLEC use

Direct FLEC measurements

Public article text states that a specially designed P-FLEC was placed on the gypsum board, and independent full-text indexing confirms P-FLEC in this article. Because the cell was the experimental tool used to investigate fungal release from the boards, the correct category is direct rather than method.

Topics

Air change rateAirborne fungal exposureERMIRelease rateSpecies compositionWater damage