2017Journal ArticleMention / reference

Time dependence of characteristic parameter for semi-volatile organic compounds (SVOCs) emitted from indoor materials

Pei, Jingjing · Yin, Yihui · Cao, Jianping · Sun, Yahong · Liu, Junjie · Zhang, Yinping

Building and Environment

In: Building and Environment, vol. 125, pp. 339 - 347, 2017, ISSN: 0360-1323.

Editorial summary

The study tracks the equilibrium gas-phase source concentration of selected phthalates from PVC flooring and TCPP from polyurethane foam during outdoor exposure and controlled chamber storage. Higher-volatility compounds declined appreciably over 60 days, whereas DEHP changed little over that period but decreased over much longer aging. FLEC is invoked through an earlier cited FLEC study that motivated the time-dependence question, not as equipment in the reported experiments.

Original editorial summary, not a verbatim abstract, based on the publisher abstract and indexed source snippets.

FLEC use

FLEC mention, comparison or reference

The reported experiments use natural exposure and a controlled ventilated chamber. The article refers to earlier values measured by Clausen and co-workers with FLEC; it does not report a new FLEC experiment.

Topics

Emission characteristicFlame retardantsIndoor air qualitySVOC sourceVapor pressure