The FLEC® has been validated and used in research for many years.
Below is a publication list of journal articles, abstracts, poster or oral presentations where the FLEC or CHEMATEC’s other products have been in focus.
If you have anything that can be added to the list, we encourage you to contact CHEMATEC.
2010 |
Clausen, Per Axel; Liu, Zhe; Xu, Ying; Kofoed-Sørensen, Vivi; Little, John C Influence of air flow rate on emission of DEHP from vinyl flooring in the emission cell FLEC: Measurements and CFD simulation Journal Article In: Atmospheric Environment, vol. 44, no. 23, pp. 2760 - 2766, 2010, ISSN: 1352-2310. Abstract | Links | BibTeX | Tags: CFD, Chamber, DEHP, Emission, FLEC, PVC @article{CLAUSEN20102760,The emission of di-(2-ethylhexyl)phthalate (DEHP) from one type of vinyl flooring with ∼15% (w/w) DEHP as plasticizer was measured at 22 °C in five FLECs + one blank FLEC (Field and Laboratory Emission Cell). Initially, the flow through all FLECs was 450 ml min−1. After 689 days the flows were changed to 1000 ml min−1, 1600 ml min−1, 2300 ml min−1, and 3000 ml min−1, respectively, in four FLECs, and kept at 450 ml min−1 in one FLEC. Air samples were collected from the effluent air at regular intervals. After 1190 days the experiments were terminated and the interior surfaces of all six FLECs were rinsed with methanol to estimate the internal surface concentrations of DEHP. The DEHP air concentration and specific emission rate (SER) at steady state was estimated for the five different flow rates. The steady-state concentrations decreased slightly with increasing air flow with only the two highest flow rates resulting in significantly lower concentrations. In contrast, the SERs increased significantly. Despite large variation, the internal surface concentrations appeared to decrease slightly with increasing FLEC flow. Computational fluid dynamic (CFD) simulations suggest that the interior gas and surface concentrations were roughly uniform for the low flow case (450 ml min−1), under which, the partitioning between the FLEC internal surface and chamber air was examined. Although paired t-tests showed no difference between CFD and experimental results for DEHP air concentrations and SERs at steady-state conditions, CFD indicated that the experimental DEHP surface concentrations in the FLECs were underestimated. In conclusion, the experiments showed that the emission of DEHP from vinyl flooring is subject to “external” control and that the SER is strongly and positively dependent on the air exchange rate. However, the increased SER almost compensates for the decrease in gas-phase concentration caused by the increased air exchange. |
2001 |
Zhu, Jiping; Cao, Xu-Liang; Beauchamp, Ray In: Environment International, vol. 26, no. 7, pp. 589 - 597, 2001, ISSN: 0160-4120. Abstract | Links | BibTeX | Tags: Chamber, Constant emission, Consumer products, Glycol ethers, Use scenario @article{ZHU2001589,Consumer products are important sources of human exposure to certain chemicals. Recent regulatory requirements for assessing human exposure to three glycol ethers, namely 2-methoxyethanol (ME), 2-ethoxyethanol (EE) and 2-butoxyethanol (BE), have prompted the investigation of these chemicals in consumer products and their emission characteristics. Thirteen products were selected for investigation based on their potential of containing the chemicals. Headspace results indicated that ME and EE were not present in any of the 13 selected products, while BE was detected in the headspace samples of seven products, of which five were household cleaning agents. Other related compounds such as 2-hexyloxyethanol (HE) and 2-(2-butoxyethoxy)ethanol (BEE) were also detected in the headspace samples of some products. BE emissions from five cleaning related products were measured using a field and laboratory emission cell (FLEC) with its subunit to provide emission data for inhalation exposure assessment purposes. These products had initial emission factors ranging from 145 to 938 mg m−2 h−1 under the experimental conditions. It was found that the emission factor of BE was inversely proportional to the dilution factor of the products. A good relationship was established between the emission factor of BE and its concentrations in water-based products. Based on product use scenarios developed by US EPA and an assumed “standard room,” average daily inhalation exposure levels of a resident as a result of performing cleaning tasks were estimated to be 0.075 and 0.186 mg (kg b.w.)−1 day−1 for two all-purpose spray cleaners, and 0.004 and 0.006 mg (kg b.w.)−1 day−1 for two-spray glass cleaners, respectively. |